线缆管理器容量指南

cable-management-capacity-example以下是十博的容量表 水平电缆架,垂直电缆架和机架 协助能力规划.

所示的值反映了实际容量和计算容量的组合,并表示100%的填充. 这些数值是使用正确敷设的电缆得出的,可能会受到电缆敷设不当的不利影响.

 Total
Area
(sq. in.)
Effective
Area
(sq. in.)
电缆直径. (mm)
0.130.150.170.190.210.230.250.270.290.310.330.35
(3.30)(3.81)(4.32)(4.83)(5.33)(5.84)(6.35)(6.86)(7.37)(7.87)(8.38)(8.89)
水平电缆管理
HCM(E)-4-1U3.041.2171534233272219161412119
HCM (E) 4-2u (- d)19.893.962341751361098974635447413632
HCM(E)-4-4U23.599.44558419326261214178151129112988677
HCM(E)-6-1U4.291.711017659473832272320171513
HCM (E) 6-2u (- d)114.645.85346260202162132110938069605347
HCM(E)-6-4U35.3414.13836628489391320267226193168147129115
PH-36.502.6015311589725849413530272321
RS(3)-RWM-13.501.40826248383126221916141211
RS(3)-RWM-29.013.60213160124998168574942373329
RS (3) -RWM-2DS19.013.60213160124998168574942373329
RS(3)-RWM-423.449.38554416324259212177150128111978676
RS(3)-RWM6-215.136.05357268209167137114968271625549
RS(3)-RWM6-433.0013.20781586456365299249211181156137121107
RWM-12.891.1668514032262118151312109
RWM-1DS12.891.1668514032262118151312109
S110-RWM - (XX)3.201.28755644352924201715131110
S110-RWM2 - (XX)8.403.36198149116937663534639343027
WM-143-52.801.1266493831252117151311109
WM-144-55.722.2913510179635143363127232118
WM-145-510.004.002361771381109075645447413632
RACKS & 垂直电缆管理
RS-07 (- s)通道18.007.204263202491991631361159885746658
RS-07(-S)前台经理6.502.6015311589725849413530272321
RS-07E通道43.5017.401029773602481394328278238206181159142
RS-07E前台经理6.502.6015311589725849413530272321
RS3-07 (- s)通道27.6011.0465349038230525020817615113111410190
RS3-07(-S)前台经理14.315.72338254198158129108917868595246
RS-CNL44.7517.901059795619495405338286245212186164146
RS-CNL326.7510.706334753702962422021711461271119887
VCM-664.8325.9315341152897718588490414355308269238211
VCM-6 Base248.2438.592283171513351069875729617529458401354315
VCM-6D390.8336.332149161412571006823686581498432378333296
VCM-6D Base261.1748.9328952174169313551109924782671581509449399
VCM-10111.5544.6226401983154312351011843713612530464409364
VCM-10 Base288.7571.004201315524561966161013421136973844738651579
VCM-10D3160.7364.293804285722241780145712151028881764669590524
VCM-10D Base2118.6594.92561642183284262921521794151813021128987871774
VCM-12134.9153.96319323981867149412231020863740641561495440
VCM-12 Base2109.0187.21516038753017241519771648139511961036907800711
VCM-12D3195.6878.2746313478270821681774147912521073930814718638
VCM-12D Base2147.39117.9169765240407932662673222818861617140112261082962
VCM-16181.6372.654298322825132012164713731162996863755667593
VCM-16 Base2149.52119.6270775316413833132712226119131640142212441098976
VCM-16D3265.57106.236285472136752942240820081699145712631105975867
VCM-16D Base2204.87163.89969772845671453937163098262222481948170515041337
VPC(A)-12前通道61.8824.7514641100856685561467396339294257227202
VPC(A)-12后通道89.5035.80211815911238991811676572491425372328292
VPC(A)-6前端通道28.8811.5568351339931926121818415813712010694
VPC(A)-6后通道44.7517.901059795619495405338286245212186164146
机柜线缆管理
小型电缆接入面板219.2515.40911684532426349291246211183160141125
机柜盖大型电缆接入面板287.5070.004142311124221939158713231120960832728642571
VP-VPC427.2010.886434833763012462051741491291139988
VP-VPC6-1 - (XX)440.8016.32965725564452370308261223194169149133
V8A-VPC4-1 - (XX)18.067.234273212502001631361159985756658
V8A-VPC6-1 - (XX)26.5610.636284723672942402001701451261109786
V8A-VPC145-1 - (XX)10.794.322551911491199781695951443935
VP-EVPC6-1 - (XX)21.008.4049737329023219015813411599877768
电缆管理
6" Hook & 环形理线器2.290.92544031252017141210987
12" Hook & 环形理线器9.173.672171631261018369585043383329
18" Hook & 环形理线器20.648.2548836628522818715613211398857567
RS-CH6.502.6015311589725849413530272321
RS-VCM / VP-VCM20.648.2548836628522818715613211398857567
S110A1RMS - (XX)3.201.28755644352924201715131110
S110A2RMS - (XX)8.403.36198149116937663534639343027
S110B1RMS - (XX)3.201.28755644352924201715131110
S110B2RMS - (XX)8.403.36198149116937663534639343027
S143/VP-1432.801.1266493831252117151311109
S1445.722.2913510179635143363127232118
S145/VP-14510.004.002361771381109075645447413632
S14618.247.3043132425220216513711610086756659
S14729.6411.8670152641032826822418916214012310896

NOTES:

  • 管理器电缆容量反映40%的计算填充率,旨在反映实际使用期间100%的填充率,因为电缆进入/出口相关的降级
  • 如果用于松弛存储, 上述容量应进一步减少50%,以适应在管理器内路由两次的单个电缆
    1. 指定的电缆容量为每边
    2. 电缆通过的开口的电缆容量仅反映80%的计算填充率,其目的是反映在实际使用过程中通过适当的电缆布线100%填充
    3. 双面管理器容量适用于整个管理器-每一方的容量可以计算为40%, 该值的50%或60%取决于内部分压器的定位
    4. 将支撑VPC背板的肩扛螺栓安装到最后方,可增加30%的线缆容量